In an error code,e.g., 16#0106, the 16# signifies that the radix of the error code is octal.

A) True
B) False

Correct Answer

verifed

verified

In setting up a module's properties, the time period entry for output information to be sent from the output tags to this output module is known as the ____________________.

Correct Answer

verifed

verified

requested packet int...

View Answer

Inhibiting a module is typically used during startups or ____________________.

Correct Answer

verifed

verified

Briefly explain what occurs when a project is downloaded into the controller and the controller is put into Run mode.

Correct Answer

verifed

verified

When a project is downloaded into the co...

View Answer

What are four general options for setting up ownership in the I/O configuration?

Correct Answer

verifed

verified

The options for setting up ownership in the I/O configuration include: 1. This controller has the module in its I/O configuration. This controller is the owner. 2. This controller has the module in its I/O configuration. This controller is not the owner and has a listen only connection. 3. This controller has the module in its I/O configuration, and the module is inhibited in the I/O configuration. 4. This controller does not have the module in the I/O configuration.

Using RSLogix 5000 software, why is configuring I/O modules a manual process rather than having a "read I/O configuration feature" as found in RSLogix 500 software?

Correct Answer

verifed

verified

Because there are many options when configuring I/O modules, the process is manual so as to provide programming individuals the opportunity to configure their systems to their exact specifications.

The conversion of the analog incoming signal to the initial value stored in the module is called the ____________________ data.

Correct Answer

verifed

verified

Until the modules are configured, no I/O tags are available in the monitor or edit tags views of the controller scoped tags collection.

A) True
B) False

Correct Answer

verifed

verified

____________________ output modules have the ability to determine the actual state of the output point when the point is commanded to be on.

Correct Answer

verifed

verified

When an integer format is selected, scaling of the outputs is not configurable in the I/O configuration.

A) True
B) False

Correct Answer

verifed

verified

Latch diagnostics can be cleared directly using a ladder logic clear instruction.

A) True
B) False

Correct Answer

verifed

verified

When selecting electronic keying, a user needs to determine how closely matched a module replacement must be to the original part number, manufacturer, and major and minor revision. What are the three choices?

Correct Answer

verifed

verified

There are three choi...

View Answer

An output module may have multiple owners, whereas an input module can only have one owner.

A) True
B) False

Correct Answer

verifed

verified

When beginning the I/O configuration process, what are three methods for selecting the module in the Select Module window?

Correct Answer

verifed

verified

First, you can select the module type from the By Category tab. Second, you can select the By Vendor tab to select by manufacturer. The third option is to select the module using the Favorites tab.

The ____________________ controller holds the I/O configuration for each module it owns.

Correct Answer

verifed

verified

Showing 1 - 15 of 15